CB-7012, CB-7014, CB-7017 Users Manual
2.2 #**
Description: Synchronized Sampling
Note: This command is for CB-7012/12D/12F/12FD/14D only.
Syntax: #**[CHK](cr)
# a Delimiter character
** synchronized sampling command
Response: No response
Example:
Command: #** No response
Send synchronized sampling command.
Command: $014 Receive: >011+025.123
First read, get status = 1.
Command: $014 Receive: >010+025.123
Second read, get status = 0.
Related Command: