Universal Library Virtual Instruments (VIs) Signal conditioning VIs
ScaleArr.VI
Scales raw data from an entire array to a user-specified range.
Summary:
Inputs: Min [SGL] - Lower limit of range
Max [SGL]- Upper limit of range
16 or 12 bit [TF] - Length of raw data; 1 to 16 bits (True), 0 to 12 bits (False =
default).
ADData [U16] - Unconverted data array
Output:
Val [SGL] - Converted data array
ErrCode [I32] - Error code. See ErrMsg.VI
Arguments:
Min Lower limit of selected range.
Max Upper limit of selected range.
16 or 12 bit Length of data to be converted. Depends on the type of hardware being used.
ADData Array with unconverted raw data.
Val Array with converted engineering data.
ErrCode Error code returned from the Universal Library. Zero if no error occurred. Use the
ErrMsg VI to convert
ErrCode into a readable string.