Measurement-computing GPIB-488 Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 116
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
Chapter 3 GPIB 488.1 Library Reference
GPIB-488 3-19 Programming Reference Manual
This call remains in effect until one of the following occurs:
Another
ibeos call is made.
ibonl or ibfind is called.
The system is re-started.
See also
ibeot
Example
This example configures the GPIB system to send the END message whenever the line feed
character is sent to a particular device. Method B described in Table 3-4, Selecting EOS, is
used (
XEOS).
C int device;
ibeos (device, XEOS + '\n');
Vista de página 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 115 116

Comentários a estes Manuais

Sem comentários