Measurement-computing TempScan/1100 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Measurement-computing TempScan/1100. Measurement Computing TempScan/1100 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 306
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - MultiScan/1200

USER’S MANUAL TempScan/1100 MultiScan/1200 High-Speed Temperature & Voltage Systems TempScan/1100 MultiScan/1200 p/n 446-0901 re

Página 2

x TempScan / MultiScan User's Manual

Página 3

5-10 System Operation 889897 TempScan / MultiScan User's Manual (1) PRINT#1, “OUTPUT07;U6X” (2) PRINT#1, “ENTER07” (3) INPUT A$ 0000006,00202

Página 4

TempScan / MultiScan User's Manual 889897 System Operation 5-11 Before all of the scan data is read, the Buffer Status String response indicat

Página 5 - Manual Layout

5-12 System Operation 889897 TempScan / MultiScan User's Manual Buffer Overrun With Multiple Trigger Blocks When more than one Trigger Block

Página 6

TempScan / MultiScan User's Manual 889897 System Operation 5-13 Buffer Buffer Read Pointer > Block 1 Trigger Blocks 1 through 5 Wr

Página 7 - Table of Contents

5-14 System Operation 889897 TempScan / MultiScan User's Manual Access to the HLL Registers You can access the HLL Registers of the TempScan/

Página 8 - 6 – System Calibration

TempScan / MultiScan User's Manual 889897 System Operation 5-15 Example 13b. Query & Clear Current HLL Registers (U5) with No HLL Termina

Página 9

5-16 System Operation 889897 TempScan / MultiScan User's Manual Example 13c. Query Last Scan Reading (U13) with Celsius & HLL Terminato

Página 10

TempScan / MultiScan User's Manual 889897 System Operation 5-17 Example 13e. Query Last Scan Reading (U13) with Volts & No HLL Terminato

Página 11 - Quick Start Guide

5-18 System Operation 889897 TempScan / MultiScan User's Manual Status-Reporting & Mask Registers The TempScan/1100 or MultiScan/1200 ha

Página 12 - CAUTION

TempScan / MultiScan User's Manual 889897 System Operation 5-19 Theory of Operation Each register is part of a hierarchy of status-reporting

Página 13 - Software Setup & Startup

446-0940, rev 2.2 988892 TempScan / MultiScan Quick Start Guide QS-1 TempScan / MultiScan Quick Start Guide High-Speed Temperature & Voltag

Página 14 - 988892 446-0940, rev 2.2

5-20 System Operation 889897 TempScan / MultiScan User's Manual Calibration Status Register (CSR) The Calibration Status Register (CSR)

Página 15 - System Overview 1

TempScan / MultiScan User's Manual 889897 System Operation 5-21 • Error Indicators (Bits 0 to 5) in Calibration Modes (10 or 11): Any calib

Página 16 - Front Panel Indicators

5-22 System Operation 889897 TempScan / MultiScan User's Manual • Channel Configuration Error (Bit 2): Set when a channel has been inappro

Página 17 - 899493 System Overview 1-3

TempScan / MultiScan User's Manual 889897 System Operation 5-23 The TempScan/1100 or MultiScan/1200 sets the Message Available Bit (MAV,Bit 4

Página 18

5-24 System Operation 889897 TempScan / MultiScan User's Manual The Event Status Enable Register (ESE) controls which events, if any, are to

Página 19

TempScan / MultiScan User's Manual 889897 System Operation 5-25 • Line 1: Configure the ESR Bit 5 (or ESB) in the STB to be set when a Device

Página 20 - WARNING

5-26 System Operation 889897 TempScan / MultiScan User's Manual Real-Time Clock The TempScan/1100 or MultiScan/1200 contains a battery-backed

Página 21 - Hardware Configuration

TempScan / MultiScan User's Manual 879596 System Calibration 6-1 System Calibration 6 Manual Calibration and Software-Automated Calibrat

Página 22 - IEEE 488 Configuration

6-2 System Calibration 879596 TempScan / MultiScan User's Manual Calibration Setup Calibration Properties For proper results, the TempScan/

Página 23

TempScan / MultiScan User's Manual 879596 System Calibration 6-3 Calibration Status Once the TempScan/1100 or MultiScan/1200 hardware write

Página 24

QS-2 TempScan / MultiScan Quick Start Guide 988892 446-0940, rev 2.2 Step 3: Connect the Unit to Your PC Prior to making a serial connection, mak

Página 25 - 899493 System Overview 1-11

6-4 System Calibration 879596 TempScan / MultiScan User's Manual Calibration of Master Chassis Note: The following text discusses the manu

Página 26

TempScan / MultiScan User's Manual 879596 System Calibration 6-5 To Calibrate the Master Chassis for Offset 1. For offset calibration, loc

Página 27 - Digital I/O Configuration

6-6 System Calibration 879596 TempScan / MultiScan User's Manual Calibration of Scanning Cards Scanning Card Calibration Channels The scann

Página 28

TempScan / MultiScan User's Manual 879596 System Calibration 6-7 The Calibrate Channel Offset (H) command – formatted as Hchan – and the Ca

Página 29

6-8 System Calibration 879596 TempScan / MultiScan User's Manual These multiple channel values are indicated in the third table. Make sure

Página 30

TempScan / MultiScan User's Manual 879596 System Calibration 6-9 To Calibrate a Thermocouple Card for Gain CAUTION Ensure that the ther

Página 31

6-10 System Calibration 879596 TempScan / MultiScan User's Manual To Calibrate a Thermocouple Card for Cold-Junction Offset CAUTION Ens

Página 32 - Line Voltage Selection

TempScan / MultiScan User's Manual 879596 System Calibration 6-11 4. Send the following Calibrate Cold Junction Offset (J) command Jchan,t

Página 33

6-12 System Calibration 879596 TempScan / MultiScan User's Manual Calibration of Voltage Scanning Cards Note: Prior to each calibration se

Página 34 - Fuse Replacement

TempScan / MultiScan User's Manual 879596 System Calibration 6-13 Calibration of RTD Scanning Cards Note: Prior to each calibration sessio

Página 35 - Bench Top

446-0940, rev 2.2 988892 TempScan / MultiScan Quick Start Guide QS-3 Reference Note: If the ERROR LED indicator starts flashing, refer to the ch

Página 36 - Power-Up Activation

6-14 System Calibration 879596 TempScan / MultiScan User's Manual

Página 37 - Expansion Units 2

TempScan / MultiScan User’s Manual 969296 Software ChartView ViewXL

Página 38 - 2-2 Expansion Units

TempScan / MultiScan User’s Manual

Página 39 - Expansion Unit 2-3

Software Reference 988992 ChartView , CV-1 ChartView Software Reference ChartView, ChartView Plus, ChartViewNET, ChartViewNET Plus, & Vie

Página 40 - CAUTIONCAUTION

CV-2 ChartView 988992 Software Reference Overview ChartView is a graphic Microsoft Windows-based program, which was designed for ease-of-use

Página 41 - Channel Assignment

Software Reference 988992 ChartView , CV-3 Acquire data with no charting or meter use (Possible Acquisition Scenarios: Acquiring and Uploading

Página 42

CV-4 ChartView 988992 Software Reference What ChartView and ChartView Plus Provide ChartView and ChartView Plus provide you with the capabil

Página 43 - Exp/11A Expansion Unit

Software Reference 988992 ChartView , CV-5 ChartView Main Window and Control Options  = Mouse, Ú= Arrow Keypads ,  = PageUp/PageDown

Página 44 - 2-8 Expansion Units

CV-6 ChartView 988992 Software Reference Channel Information Region Channels can return values in units of °C, °F, °K, °R, mV, V, or user def

Página 45 - Expansion Unit 2-9

Software Reference 988992 ChartView , CV-7 Units/div - The units in units/div (18) can be °C, °F, °K, °R, mV, or V. The division referenced is

Página 46

QS-4 TempScan / MultiScan Quick Start Guide 988892 446-0940, rev 2.2 5. In the Automatic Chart Creation portion of the Chart Setup Wizard box, cl

Página 47

CV-8 ChartView 988992 Software Reference Chart Pop-up Menu ChartView Main Window with Chart Pop-up Menu and “Chart Properties”Dialog Box Wh

Página 48 - 2-12 Expansion Units

Software Reference 988992 ChartView , CV-9 • Properties - Selecting “Properties” from the pop-up menu accesses a Chart Properties dialog box.

Página 49 - Scanning Cards 3

CV-10 ChartView 988992 Software Reference (1) Look at the channel selection box to ensure that the desired channel is shown. If not, select

Página 50 - 3-2 Scanning Cards

Software Reference 988992 ChartView , CV-11 Main Window Toolbar Each item in the toolbar, with exception of Group Select (1), is represented by

Página 51 - Scanning Cards 3-3

CV-12 ChartView 988992 Software Reference Display Configuration The Display Configuration button accesses a Display Configuration Setup di

Página 52 - 3-4 Scanning Cards

Software Reference 988992 ChartView , CV-13 Display Configuration Setup Dialog Box with an Existing Configuration Note: When a chart contain

Página 53

CV-14 ChartView 988992 Software Reference Adjusting Channel Setup for Channel 1 ChartView and ChartView Plus data channels can operate in on

Página 54 - 3-6 Scanning Cards

Software Reference 988992 ChartView , CV-15 Manually Creating a Display For ChartView Plus users, if you plan to have a chart setup that is not

Página 55 - MultiScan Scanning Cards

CV-16 ChartView 988992 Software Reference 4. As seen in the previous figure for the “Clean Slate” approach, you have two options at this

Página 56 - 3-8 Scanning Cards

Software Reference 988992 ChartView , CV-17 9. Choose channels for the selected chart. With ChartView Plus, you can select up to four overlap

Página 57 - Scanning Cards 3-9

TempScan / MultiScan User’s Manual 899493 System Overview 1-1 System Overview 1 Introduction ... 1-1 TempScan/1100 ... 1-1 MultiScan/1200 ...

Página 58 - 3-10 Scanning Cards

CV-18 ChartView 988992 Software Reference Remember, you can enable additional channels from the Channel and Alarm Setup window. Enabling add

Página 59 - System Configuration 4

Software Reference 988992 ChartView , CV-19 Arm Acquisition You can use the Arm Acquisition button to activate an acquisition. When you clic

Página 60 - Memory Allocation

CV-20 ChartView 988992 Software Reference Main Window Pull-Down Menus The ChartView main window features several pull-down menus. As an al

Página 61

Software Reference 988992 ChartView , CV-21 When ChartView is started for the very first time there is no default channel configuration file

Página 62

CV-22 ChartView 988992 Software Reference Display config. Allows you to: Open a previously saved display configuration file, save the curre

Página 63

Software Reference 988992 ChartView , CV-23 View (continued) Timestamps & Chartspeed A 9 by Timestamps & Chartspeed indicates the optio

Página 64 - Required Configuration

CV-24 ChartView 988992 Software Reference Acquisition Auto Re-Arm Trigger and Overwrite Options Automatic Keyboard Trigger on Auto Re-Arm

Página 65

Software Reference 988992 ChartView , CV-25 Data Upload Data During Acquisition (automatic control) Enables ChartView to retrieve scans from

Página 66

CV-26 ChartView 988992 Software Reference Convert Existing Files You may find that you need to convert data files from one format to another

Página 67 - Scan Configuration

Software Reference 988992 ChartView , CV-27 Setup RS-232 The RS-232 Setup dialog box appears. If “Yes” is chosen for modem, the RS-232 Setup w

Página 68 - I? command

1-2 System Overview 899493 TempScan / MultiScan User's Manual Front Panel Indicators Ten (10) LED indicators on the front panel of either

Página 69

CV-28 ChartView 988992 Software Reference Setup Network Setup Network is a purchased option that provides a means of configuring systems tha

Página 70

Software Reference 988992 ChartView , CV-29 Device … Status ¾ Instrument Inventory Accesses the System Inventory dialog box. System I

Página 71 - Acquisition Configuration

CV-30 ChartView 988992 Software Reference From the Alarm configuration dialog box, you can define the information that will be saved in the l

Página 72

Software Reference 988992 ChartView , CV-31 Instrument Realtime Clock Brings up the Device System Time dialog box. You can adjust the time and

Página 73

CV-32 ChartView 988992 Software Reference Bar Graph Meters Selecting Bar Graph Meters from ChartView’s Window pull-down menu brings up the Ba

Página 74 - Trigger Configuration

Software Reference 988992 ChartView , CV-33 Analog Meters Selecting Analog Meters from ChartView’s Window pull-down menu brings up the Analog M

Página 75

CV-34 ChartView 988992 Software Reference Digital Meters Selecting Digital Meters from ChartView’s Window pull-down menu brings up the Digit

Página 76 - Additional Configuration

Software Reference 988992 ChartView , CV-35 Meter Toolbars The toolbars for the three types of meters are identical, with exception that the D

Página 77 - Alarm Configuration

CV-36 ChartView 988992 Software Reference Meters Configuration Menu A meters configuration menu (lower left corner of figure) will appear whe

Página 78

Software Reference 988992 ChartView , CV-37 Configure Meter Settings, Function Descriptions Function Description 1 Select Channel Select a new

Página 79

TempScan / MultiScan User’s Manual 899493 System Overview 1-3 Rear Panel Switches & Connectors Two (2) switches, seven (7) connectors, one (1

Página 80 - Stamp Configuration

CV-38 ChartView 988992 Software Reference Channel and Alarm Setup Dialog Box Channel and Alarm Setup, Button Descriptions (1) – Turn On All

Página 81 - (4) INPUT A$

Software Reference 988992 ChartView , CV-39 Channel Configuration Columns 1) Channel (CH) ⎯ This column serves only as a channel number indicat

Página 82

CV-40 ChartView 988992 Software Reference Note: When using a channel as a reference channel, remember that lower numbered channels are calcu

Página 83

Software Reference 988992 ChartView , CV-41 Acquisition Setup Dialog Box The information entered in the Acquisition Setup dialog box is used by

Página 84 - Data Format Configuration

CV-42 ChartView 988992 Software Reference In the High-speed, single-channel (burst mode), all ChartView display functions are intentionally

Página 85

Software Reference 988992 ChartView , CV-43 The assigned channels will be “ON” in the Channel Configuration portion of the Channel and Alarm Set

Página 86

CV-44 ChartView 988992 Software Reference This Warning Appears Prior to Enabling the Burst Mode • The Burst Mode channel will be the only

Página 87

Software Reference 988992 ChartView , CV-45 Question 2: How do I measure a 60 cycle waveform using just one channel? Answer: To measure AC, y

Página 88

CV-46 ChartView 988992 Software Reference Data Destination Dialog Box The Data Destination dialog box can be accessed from the Setup Channel

Página 89

Software Reference 988992 ChartView , CV-47 Why use Auto Re-Arm? You can use Auto Re-Arm as a convenient way to monitor and analyze specific ty

Página 90 - Power-Up Configuration

1-4 System Overview 899493 TempScan / MultiScan User's Manual TempScan/1100 & MultiScan/1200 Specifications CAUTION Please read this

Página 91 - System Operation 5

CV-48 ChartView 988992 Software Reference Chart Setup Wizard Introduction Chart Setup Wizard is a feature of ChartView and ChartView Plus

Página 92 - Buffer Organization

Software Reference 988992 ChartView , CV-49 A Manual Chart Creation, Create Charts button allows you to bypass the Chart Setup Wizard and enter

Página 93 - Trigger Block Configurations

CV-50 ChartView 988992 Software Reference It is a simple task to create chart display configurations using the automatic method. The followi

Página 94 - Buffer Query Operation

989092 457-0913 rev 3.0 ViewXL Software Reference Overview …… vxl-1 Program Requirements …… vxl-1 Installation of ViewXL Add-in …… vxl-1

Página 95 - Buffer Read Operations

vxl-2 ViewXL 989092 Software Reference Menu ViewXL Menu The ViewXL menu gives you access to all of the Add-Ins features. The first six me

Página 96

989092 457-0913 rev 3.0 Toolbar The ViewXL toolbar provides access to the Add-Ins most frequently used features. These features, and a few

Página 97

vxl-4 ViewXL 989092 Software Reference Load Configuration When pushed, the Load Configuration dialog box appears with a list of configurat

Página 98

989092 457-0913 rev 3.0  Enable Server file conversion. This option enables the post acquisition file conversion for the specified format t

Página 99

vxl-6 ViewXL 989092 Software Reference Multiple Data Files This option selects how the files are displayed if either: (a) an acquisition con

Página 100

989092 457-0913 rev 3.0 If the ViewXL Add-In is running while connected to a data acquisition application, e.g., ChartView or DaqView), then

Página 101 - Buffer Overrun

TempScan / MultiScan User’s Manual 899493 System Overview 1-5 Data Storage & Format Storage: 128 K reading (256 Kbyte) standard; optional 500 K

Página 102

vxl-8 ViewXL 989092 Software Reference The "Channel Information" panel (see previous figure, right-side, lower section) displays a

Página 103 - F) command

989092 457-0913 rev 3.0 Selecting VIEWXL from Available References You have now performed the tasks needed to use the ViewXL Add-In from you

Página 104 - Access to the HLL Registers

vxl-10 ViewXL 989092 Software Reference 3. Inside the Macro (between the Sub and End Sub lines) type in the string "viewxl.interface&

Página 105

989092 457-0913 rev 3.0 ViewXL API Definition ViewXL provides a limited set of methods that you can use in your own Excel macros to leverage

Página 106

vxl-12 ViewXL 989092 Software Reference Public Function vxlIsAcquiring() As Boolean This function returns True if the Server is Armed and ac

Página 107

TempScan / MultiScan User’s Manual 969296 APPENDICES Appendix A – API Command Reference Appen

Página 108 - 5-18 System Operation

TempScan / MultiScan User’s Manual

Página 109 - Status-Reporting Registers

TempScan / MultiScan User’s Manual 889897 API Command Reference A-1 Appendix A - API Command Reference A Introduction …… A-2 Command Syntax …… A-2

Página 110 - 5-20 System Operation

A-2 API Command Reference 889897 TempScan / MultiScan User’s Manual Introduction Command Syntax Command Characters Commands are identified with t

Página 111 - System Operation 5-21

TempScan / MultiScan User’s Manual 889897 API Command Reference A-3 Fixed Formats Any command with the Query (?) command extension or any User Stat

Página 112 - 5-22 System Operation

TempScan / MultiScan User’s Manual

Página 113 - Mask Registers

1-6 System Overview 899493 TempScan / MultiScan User's Manual Digital I/O Interface & Alarms Installation Category: For CE: Category 1.

Página 114

A-4 API Command Reference 889897 TempScan / MultiScan User’s Manual Table 16a. Immediate & Deferred Commands Command TempScan/1100 MultiSc

Página 115 - Additional Operation

TempScan / MultiScan User’s Manual 889897 API Command Reference A-5 Table 16b. Deferred Commands Execution Order Order TempScan/1100 MultiScan/1

Página 116 - Real-Time Clock

A-6 API Command Reference 889897 TempScan / MultiScan User’s Manual Command Summary Command Syntax Description @ Trigger On Command @ Trig

Página 117 - System Calibration 6

TempScan / MultiScan User’s Manual 889897 API Command Reference A-7 Command Syntax Description C# Select Card C#card Select the card from wh

Página 118 - Calibration Setup

A-8 API Command Reference 889897 TempScan / MultiScan User’s Manual Command Syntax Description J Calibrate Cold Junction Offset Jchan, typ

Página 119 - Calibration Password

TempScan / MultiScan User’s Manual 889897 API Command Reference A-9 Command Syntax Description Obank1, bank2, bank3, bank4 Set any of the 32

Página 120 - K12345

A-10 API Command Reference 889897 TempScan / MultiScan User’s Manual Command Syntax Description U User Status Ureq Request information abo

Página 121

TempScan / MultiScan User’s Manual 889897 API Command Reference A-11 Command Reference The following pages provide the command set for the TempScan/

Página 122

A-12 API Command Reference 889897 TempScan / MultiScan User’s Manual @ - Trigger On Command TYPE Acquisition EXECUTION Deferred SYNTAX @ Trigg

Página 123

TempScan / MultiScan User’s Manual 889897 API Command Reference A-13 *B - Flush Acquisition Buffer TYPE Buffer EXECUTION Immediate SYNTAX *B Fl

Página 124

TempScan / MultiScan User’s Manual 899493 System Overview 1-7 Calibration Calibration of cold junction sensor: Software control of calibrated thermo

Página 125

A-14 API Command Reference 889897 TempScan / MultiScan User’s Manual *C - Clear Channel Configuration TYPE Channel EXECUTION Deferred SYNTAX

Página 126

TempScan / MultiScan User’s Manual 889897 API Command Reference A-15 *F - Restore Factory Settings TYPE System EXECUTION Immediate SYNTAX *F Re

Página 127

A-16 API Command Reference 889897 TempScan / MultiScan User’s Manual *G - Set RTD Gain Calibration Reference TempScan/1100 only TYPE Calibrat

Página 128

TempScan / MultiScan User’s Manual 889897 API Command Reference A-17 *K - Change Calibration Keyword TYPE Calibration EXECUTION Immediate SYNTA

Página 129

A-18 API Command Reference 889897 TempScan / MultiScan User’s Manual *P - Adjust Calibration Card Pots TYPE Calibration EXECUTION Immediate S

Página 130

TempScan / MultiScan User’s Manual 889897 API Command Reference A-19 *R - Reset Power-On TYPE System EXECUTION Immediate SYNTAX *R Power-on res

Página 131 - Software

A-20 API Command Reference 889897 TempScan / MultiScan User’s Manual *S - Set Power-Up Configuration TYPE System EXECUTION Immediate SYNTAX *

Página 132

TempScan / MultiScan User’s Manual 889897 API Command Reference A-21 *T - Set Scan Time Stamping TYPE System EXECUTION Immediate SYNTAX *Tstate

Página 133 - C3523DFA6C0A

A-22 API Command Reference 889897 TempScan / MultiScan User’s Manual *W - Set Software Digital Filtering TempScan/1100 only TYPE System EXECU

Página 134 - Overview

TempScan / MultiScan User’s Manual 889897 API Command Reference A-23 A - Assign Digital Alarm Output TYPE System EXECUTION Deferred SYNTAX Acha

Página 135 - 1) Waiting for Trigger

1-8 System Overview 899493 TempScan / MultiScan User's Manual The rear panel DIP switch is read only during power-on or reset and should be

Página 136 - Main Window

A-24 API Command Reference 889897 TempScan / MultiScan User’s Manual A# - Set Scan Alarm Stamping TYPE System EXECUTION Deferred SYNTAX A#sta

Página 137 - 988992 ChartView , CV-5

TempScan / MultiScan User’s Manual 889897 API Command Reference A-25 C - Configure Channels TYPE Channel EXECUTION Deferred SYNTAX Cchans, type

Página 138 - Channel Information Region

A-26 API Command Reference 889897 TempScan / MultiScan User’s Manual Thermocouple Scanning Cards Thermocouple Type Assignable Channel Types

Página 139 - Status Indicator Region

TempScan / MultiScan User’s Manual 889897 API Command Reference A-27 EXAMPLE PRINT#1, “OUTPUT07; F0,0X” ‘ Set Data Format to Engineering Units, d

Página 140 - Chart Pop-up Menu

A-28 API Command Reference 889897 TempScan / MultiScan User’s Manual C# - Select Card TYPE Calibration EXECUTION Immediate SYNTAX C#card Sele

Página 141 - 988992 ChartView , CV-9

TempScan / MultiScan User’s Manual 889897 API Command Reference A-29 D# - Set Relay Make Time MultiScan/1200 only TYPE System EXECUTION Deferre

Página 142 - Software Reference

A-30 API Command Reference 889897 TempScan / MultiScan User’s Manual E - End Calibration Mode TYPE Calibration EXECUTION Immediate SYNTAX E T

Página 143 - Main Window Toolbar

TempScan / MultiScan User’s Manual 889897 API Command Reference A-31 E? - Query Error Status TYPE System EXECUTION Immediate SYNTAX E? Returns

Página 144 - Configuration

A-32 API Command Reference 889897 TempScan / MultiScan User’s Manual F - Set Data Format TYPE System EXECUTION Deferred SYNTAX Fengr, format

Página 145 - 988992 ChartView , CV-13

TempScan / MultiScan User’s Manual 889897 API Command Reference A-33 When the unit is inputting or outputting data, it first references the curren

Página 146 - CV-14 ChartView

TempScan / MultiScan User’s Manual 899493 System Overview 1-9 RS-232/RS-422 Serial Configuration Alternatively, the TempScan/1100 or MultiScan/1200

Página 147 - 988992 ChartView , CV-15

A-34 API Command Reference 889897 TempScan / MultiScan User’s Manual F# - Set Burst Mode Frequency MultiScan/1200 only TYPE System EXECUTION

Página 148 - 988992 Software Reference

TempScan / MultiScan User’s Manual 889897 API Command Reference A-35 G - Calibrate Channel Gain TYPE Calibration EXECUTION Immediate SYNTAX Gch

Página 149 - 988992 ChartView , CV-17

A-36 API Command Reference 889897 TempScan / MultiScan User’s Manual H - Calibrate Channel Offset TYPE Calibration EXECUTION Immediate SYNTAX

Página 150 - View File Data

TempScan / MultiScan User’s Manual 889897 API Command Reference A-37 I - Set Scan Interval TYPE Acquisition EXECUTION Deferred SYNTAX Inorm, ac

Página 151 - 988992 ChartView , CV-19

A-38 API Command Reference 889897 TempScan / MultiScan User’s Manual I# - Set Digital Input Stamping TYPE System EXECUTION Deferred SYNTAX I#

Página 152 - Main Window Pull-Down Menus

TempScan / MultiScan User’s Manual 889897 API Command Reference A-39 J - Calibrate Cold Junction Offset TYPE Calibration EXECUTION Immediate SY

Página 153 - 988992 ChartView , CV-21

A-40 API Command Reference 889897 TempScan / MultiScan User’s Manual K - Enter Calibration Mode TYPE Calibration EXECUTION Immediate SYNTAX K

Página 154

TempScan / MultiScan User’s Manual 889897 API Command Reference A-41 L - Set Trigger Level TYPE Channel EXECUTION Deferred SYNTAX Lchan, level,

Página 155 - View (continued)

A-42 API Command Reference 889897 TempScan / MultiScan User’s Manual L# - Set Scan Rate TempScan/1100 only TYPE System EXECUTION Deferred SYN

Página 156 - Acquire

TempScan / MultiScan User’s Manual 889897 API Command Reference A-43 M - Set SRQ Mask TYPE System EXECUTION Deferred SYNTAX Mmask Use the IEEE

Página 157 - 988992 ChartView , CV-25

1-10 System Overview 899493 TempScan / MultiScan User's Manual 4. If configured for RS-422, the port’s Receive Data (RxD+) and Clear to

Página 158 - Device … Interface ¾

A-44 API Command Reference 889897 TempScan / MultiScan User’s Manual M# - Set Measuring Mode MultiScan/1200 only TYPE System EXECUTION Deferr

Página 159 - 988992 ChartView , CV-27

TempScan / MultiScan User’s Manual 889897 API Command Reference A-45 N - Set Event Mask TYPE System EXECUTION Deferred SYNTAX Nmask Directly se

Página 160

A-46 API Command Reference 889897 TempScan / MultiScan User’s Manual O - Set Digital Outputs TYPE System EXECUTION Immediate SYNTAX Obank1, b

Página 161 - Device … Status ¾

TempScan / MultiScan User’s Manual 889897 API Command Reference A-47 P - Program Trigger Times TYPE Channel EXECUTION Deferred SYNTAX Pstart, s

Página 162

A-48 API Command Reference 889897 TempScan / MultiScan User’s Manual Q - Set Query Terminator TYPE System EXECUTION Deferred SYNTAX Qresp, hl

Página 163 - 988992 ChartView , CV-31

TempScan / MultiScan User’s Manual 889897 API Command Reference A-49 QC? - Query Card Data TYPE Calibration EXECUTION Immediate SYNTAX QC? Read

Página 164 - Bar Graph Meters

A-50 API Command Reference 889897 TempScan / MultiScan User’s Manual R - Read Buffered Data TYPE Buffer EXECUTION Immediate SYNTAX Rtype Read

Página 165 - Analog Meters

TempScan / MultiScan User’s Manual 889897 API Command Reference A-51 R# - Read Last Readings TYPE System EXECUTION Immediate SYNTAX R#chans Que

Página 166 - Digital Meters

A-52 API Command Reference 889897 TempScan / MultiScan User’s Manual S - Set Real-Time Clock TYPE System EXECUTION Immediate SYNTAX Stime Set

Página 167 - Meter Pull-Down Menus

TempScan / MultiScan User’s Manual 889897 API Command Reference A-53 T - Set Trigger Configuration TYPE Acquisition EXECUTION Deferred SYNTAX T

Página 168 - Configuring a Meter

TempScan / MultiScan User’s Manual 899493 System Overview 1-11 Handshaking. When the RS-232 port is used, the type of handshaking must be selected

Página 169 - Setup Window

A-54 API Command Reference 889897 TempScan / MultiScan User’s Manual For more information on Trigger and Stop configuration, see section Trigger

Página 170

TempScan / MultiScan User’s Manual 889897 API Command Reference A-55 U - User Status TYPE System EXECUTION Immediate SYNTAX Ureq Request inform

Página 171 - 988992 ChartView , CV-39

A-56 API Command Reference 889897 TempScan / MultiScan User’s Manual • U3: Query the current system settings. This request is equivalent to th

Página 172 - CV-40 ChartView

TempScan / MultiScan User’s Manual 889897 API Command Reference A-57 • U15: Query the product information. This request responds with the curren

Página 173 - Acquisition Setup Dialog Box

A-58 API Command Reference 889897 TempScan / MultiScan User’s Manual V - Set User Terminator TYPE System EXECUTION Deferred SYNTAX Vval Set t

Página 174 - Acquisition Setup

TempScan / MultiScan User’s Manual 889897 API Command Reference A-59 W# - Set Averaging Weight MultiScan/1200 only TYPE System EXECUTION Deferr

Página 175 - 988992 ChartView , CV-43

A-60 API Command Reference 889897 TempScan / MultiScan User’s Manual X - Execute TYPE System EXECUTION Immediate SYNTAX X Execute preceding c

Página 176 - CV-44 ChartView

TempScan / MultiScan User’s Manual 889897 API Command Reference A-61 Y - Set Counts TYPE Acquisition EXECUTION Deferred SYNTAX Ypre, post, stop

Página 177 - 988992 ChartView , CV-45

A-62 API Command Reference 889897 TempScan / MultiScan User’s Manual ? - Query TYPE System EXECUTION Immediate SYNTAX ? Query the present con

Página 178 - Data Destination Dialog Box

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-1 Appendix B – IEEE 488, Serial, and ASCII B IEEE 488 Bus & Serial Bu

Página 179 - 988992 ChartView , CV-47

1-12 System Overview 899493 TempScan / MultiScan User's Manual A CA-47 cable connects the unit with the computer. The TempScan/1100 or Mult

Página 180 - Chart Setup Wizard

B-2 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B …… A-IEEE 488 Bus Commands Bus State IEEE 488 Bus C

Página 181 - 988992 ChartView , CV-49

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-3 …… A-ASCII Codes …… A-ASCII Code Summary …… A-Decimal Values 00 to 63

Página 182 - CV-50 ChartView

B-4 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B …… A-Decimal Values 64 to 127 – TAG & SCG Box

Página 183 - ViewXL

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-5 …… A-ASCII Code Details …… A-Decimal Values 00 to 31 – ACG & UCG Ch

Página 184 - 989092 Software Reference

B-6 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B …… A-Decimal Values 00 to 31 – ACG & UCG Descri

Página 185 - Toolbar

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-7 …… A-Decimal Values 32 to 63 – LAG ASCII Character Set (Decimal 32 to 63

Página 186 - Data Acquisition Server

B-8 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B …… A-Decimal Values 64 to 95 – TAG ASCII Character

Página 187 - Timestamps

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-9 …… A-Decimal Values 96 to 127 – SCG ASCII Character Set (96 to 127) Dec

Página 188 - Import Files

B-10 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B Abbreviations  (bullet symbol) “and” (e.g. *SC

Página 189 - 457-0913 rev 3.0

TempScan/MultiScan, Appendix B 889597 IEEE488, Serial, & ASCII B-11 SCPI Standard Cmds. for Programmable Instruments SUB Substitute (ASCII C

Página 190

TempScan / MultiScan User’s Manual 899493 System Overview 1-13 • Clear To Send Positive (CTS+): This input pin is used as a hardware handshake line

Página 191 - An Example Macro

B-12 IEEE 488, Serial, & ASCII 889597 TempScan/MultiScan, Appendix B

Página 192 - Sub GetData()

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-1 Appendix C – Program Examples in Quick Basic C Introduction …… C-1

Página 193 - ViewXL API Definition

C-2 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The QuickBASIC PRINT and INPUT commands are used to communicate with

Página 194

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-3 Reading HLL Status TempScan/1100 Example 15a. HLL32.BAS Program (1)

Página 195 - APPENDICES

C-4 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C MultiScan/1200 Example 15b. HLL24.BAS Program (1) …… 15-CLS : PRINT

Página 196

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-5 Reading HLL Data from Thermocouple & Volts Cards TempScan/1100 Ex

Página 197 - Command Reference …… A-11

C-6 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C MultiScan/1200 Example 15d. HLL48.BAS Program (1) …… 15-CLS : PRINT

Página 198 - Introduction

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-7 • Lines 17-29: Until another key is pressed to exit the loop, the U4

Página 199 - Command Interpretation

C-8 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C (42) …… 15- …… 15-PRINT #1 “OUTPUT 07; R1X” …… 15- …… 15-PRINT #1 “

Página 200 - Immediate Immediate

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-9 MultiScan/1200 Example 15f. SLOW_ACQ.BAS Program (1) …… 15-CLS : PRI

Página 201

1-14 System Overview 899493 TempScan / MultiScan User's Manual DB50 Digital I/O Pin Descriptions Line Pin Line Pin Line Pin Line Pin

Página 202 - Command Summary

C-10 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C This program is SLOW_ACQ.BAS in the \EXAMPLES\ subdirectory. It wi

Página 203

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-11 Acquiring Pre- & Post-Trigger Data at the Same Rate TempScan/110

Página 204

C-12 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C • Lines 1-3: Although not necessary, it is good practice to reset

Página 205

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-13 MultiScan/1200 Example 15h. FAST_ACQ.BAS Program (1) …… 15-CLS : PR

Página 206

C-14 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C • Lines 1-3: Although not necessary, it is good practice to reset

Página 207 - Command Reference

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-15 Operating Alarms TempScan/1100 Example 15i. ALARM2.BAS Program (1)

Página 208 - - Trigger On Command

C-16 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is ALARM2.BAS in the \EXAMPLES\ subdirectory.

Página 209

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-17 MultiScan/1200 Example 15j. ALARM2.BAS Program (1) …… 15-CLS : PRIN

Página 210

C-18 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is ALARM2.BAS in the \EXAMPLES\ subdirectory.

Página 211

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-19 Using the IEEE 488 SRQ with Alarms TempScan/1100 Example 15k. ALAR2

Página 212 - TempScan/1100 only

TempScan / MultiScan User’s Manual 899493 System Overview 1-15 Expanded Memory Configuration The TempScan/1100 or MultiScan/1200 can accommodate 8

Página 213

C-20 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is ALAR2SRQ.BAS in the \EXAMPLES\ subdirector

Página 214

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-21 MultiScan/1200 Example 15l. ALAR2SRQ.BAS Program (1) …… 15-CLS : PR

Página 215 - - Reset Power-On

C-22 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is ALAR2SRQ.BAS in the \EXAMPLES\ subdirector

Página 216

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-23 Acquiring Buffer Data in Binary Format TempScan/1100 Example 15m. B

Página 217

C-24 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BIN_ACQ.BAS in the \EXAMPLES\ subdirectory

Página 218

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-25 MultiScan/1200 Example 15n. BIN_ACQ.BAS Program (1) …… 15-CLS : PRI

Página 219

C-26 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BIN_ACQ.BAS in the \EXAMPLES\ subdirectory

Página 220

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-27 Acquiring HLL Data in Binary Format TempScan/1100 Example 15o. BIN_

Página 221 - - Configure Channels

C-28 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BIN_HLL.BAS in the \EXAMPLES\ subdirectory

Página 222

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-29 MultiScan/1200 Example 15p. BIN_HLL.BAS Program (1) …… 15-CLS : PRI

Página 223

TempScan / MultiScan User’s Manual Warranty Information Your IOtech warranty is as stated on the product warranty card. You may contact IOte

Página 224 - - Select Card

1-16 System Overview 899493 TempScan / MultiScan User's Manual Scanning Card & Channel Expansion Scanning Card Expansion Each Tem

Página 225 - MultiScan/1200 only

C-30 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BIN_HLL.BAS in the \EXAMPLES\ subdirectory

Página 226 - - End Calibration Mode

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-31 Using Auto Re-arm to Capture Multiple Trigger Blocks TempScan/1100 E

Página 227 - - Query Error Status

C-32 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BLK_ACQ.BAS in the \EXAMPLES\ subdirectory

Página 228 - - Set Data Format

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-33 MultiScan/1200 Example 15r. BLK_ACQ.BAS Program (1) …… 15-CLS : PRI

Página 229

C-34 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BLK_ACQ.BAS in the \EXAMPLES\ subdirectory

Página 230

TempScan / MultiScan, Appendix C 879696 Program Examples in Quick Basic C-35 Acquiring Burst Mode Data (MultiScan/1200 Only) Example 15s. BURST.

Página 231

C-36 Program Examples in Quick Basic 879696 TempScan / MultiScan, Appendix C The following program is BURST.BAS in the \EXAMPLES\ subdirectory.

Página 232

TempScan / MultiScan User’s Manual 899493 System Overview 1-17 Channel Expansion The TempScan/1100 system can be expanded up to 992 channels, while

Página 233 - - Set Scan Interval

1-18 System Overview 899493 TempScan / MultiScan User's Manual To change the operating voltage of the TempScan/1100, MultiScan/1200, Exp/10A

Página 234

TempScan / MultiScan User’s Manual 899493 System Overview 1-19 CAUTION It is possible to place the line voltage switch (S2 or SW2) in a partia

Página 235

1-20 System Overview 899493 TempScan / MultiScan User's Manual Fuse Replacement The TempScan/1100, MultiScan/1200, Exp/10A and Exp/11A each

Página 236

TempScan / MultiScan User’s Manual 899493 System Overview 1-21 Rack-Mount & Bench-Top Assembly The TempScan/1100, MultiScan/1200, Exp/10A and

Página 237 - - Set Trigger Level

1-22 System Overview 899493 TempScan / MultiScan User's Manual Power-Up Activation At initial power-up or on the Reset Power-On (*R) comman

Página 238 - - Set Scan Rate

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-1 Expansion Units 2 Exp/10A Expansion Unit ... 2-1 Introduction ... 2-1 Fro

Página 239 - - Set SRQ Mask

2-2 Expansion Units 889897 TempScan / MultiScan User's Manual Rear Panel Switches & Connectors Two (2) switches, three (3) connectors

Página 240 - - Set Measuring Mode

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-3 Exp/10A Specifications CCCCAUTIONAUTIONAUTIONAUTION Please read this manu

Página 241 - - Set Event Mask

TempScan / MultiScan User’s Manual

Página 242 - - Set Digital Outputs

2-4 Expansion Units 889897 TempScan / MultiScan User's Manual Exp/10A Hardware Configuration Master/Slave Connection Up to fifteen Exp/10A e

Página 243 - - Program Trigger Times

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-5 Slave Configuration CAUTIONCAUTIONCAUTIONCAUTION Avoid linking two or more ex

Página 244 - - Set Query Terminator

2-6 Expansion Units 889897 TempScan / MultiScan User's Manual Exp/10A Slave Address Settings Exp/10A Channel Assignments Microswitches 5 t

Página 245 - - Query Card Data

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-7 Exp/11A Expansion Unit Introduction All Exp/11A components are carefully inspect

Página 246 - - Read Buffered Data

2-8 Expansion Units 889897 TempScan / MultiScan User's Manual Two (2) switches, three (3) connectors, one (1) grounding nut, and ten (10) inp

Página 247 - - Read Last Readings

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-9 WARNINGWARNINGWARNINGWARNING Service: This product contains no operator serv

Página 248 - - Set Real-Time Clock

2-10 Expansion Units 889897 TempScan / MultiScan User's Manual 4. Plug in all system devices. 5. Set the slave address on the rear panel

Página 249

TempScan / MultiScan User's Manual 889897 Expansion Unit 2-11 Channel Assignment Channels 1 through 32 are always in the TempScan/1100, and c

Página 250

2-12 Expansion Units 889897 TempScan / MultiScan User's Manual

Página 251 - - User Status

TempScan / MultiScan User's Manual 889897 Scanning Cards 3-1 Scanning Cards 3 TempScan Scanning Cards ... 3-1 TempTC/32B Thermocouple Sca

Página 252

TempScan / MultiScan User’s Manual 879596 v Manual Layout Note: For benefit of those who have not yet i

Página 253

3-2 Scanning Cards 889897 TempScan / MultiScan User's Manual TempTC/32B Thermocouple Scanning Card TempTC/32B Specifications Note: These

Página 254 - - Set User Terminator

TempScan / MultiScan User's Manual 889897 Scanning Cards 3-3 Fault Detection: Open thermocouple may be detected by a software query. Cold Jun

Página 255 - - Set Averaging Weight

3-4 Scanning Cards 889897 TempScan / MultiScan User's Manual TempV/32B Voltage Scanning Card TempV/32B Specifications Note: These spec

Página 256 - - Execute

TempScan / MultiScan User's Manual 889897 Scanning Cards 3-5 TempV/32B Description The TempV/32B voltage scanning module contains 32 differen

Página 257 - - Set Counts

3-6 Scanning Cards 889897 TempScan / MultiScan User's Manual TempRTD/16B RTD Scanning Card TempRTD/16B Specifications Note: These specifi

Página 258 - - Query

TempScan / MultiScan User's Manual 889897 Scanning Cards 3-7 MultiScan Scanning Cards The MultiScan/1200 master unit and any Exp/10A and Exp/

Página 259

3-8 Scanning Cards 889897 TempScan / MultiScan User's Manual MTC/24 Thermocouple/Volt Scanning Card MTC/24 Specifications Note: These spe

Página 260 - IEEE 488 Bus Commands

TempScan / MultiScan User's Manual 889897 Scanning Cards 3-9 Fault Detection: Open thermocouple may be detected by a software query. Col

Página 261 - ASCII Codes

3-10 Scanning Cards 889897 TempScan / MultiScan User's Manual MHV/24 High-Voltage Scanning Card MHV/24 Specifications Note: These specifi

Página 262

TempScan / MultiScan User's Manual 879596 System Configuration 4-1 System Configuration 4 Introduction …… 4-1 Memory Allocation …… 4-2 Meas

Página 263 - ASCII Code Details

vi TempScan / MultiScan User’s Manual

Página 264

4-2 System Configuration 879596 TempScan / MultiScan User's Manual Memory Allocation Each TempScan/1100 and MultiScan/1200 unit comes equi

Página 265

TempScan / MultiScan User's Manual 879596 System Configuration 4-3 Note: (1) For DC voltage and temperature, the term averaging implies obt

Página 266

4-4 System Configuration 879596 TempScan / MultiScan User's Manual Note: The MultiScan/1200 unit only supports the measurement of AC volta

Página 267

TempScan / MultiScan User's Manual 879596 System Configuration 4-5 Single-Channel High-Speed Burst Mode In single-channel high-speed burst

Página 268 - Abbreviations

4-6 System Configuration 879596 TempScan / MultiScan User's Manual Required Configuration Although most of the user-defined configuration

Página 269

TempScan / MultiScan User's Manual 879596 System Configuration 4-7 Channel Configuration The TempScan/1100 or MultiScan/1200 unit performs

Página 270

4-8 System Configuration 879596 TempScan / MultiScan User's Manual Configuring TempTC/32B Thermocouple Channels (TempScan/1100 Only) If th

Página 271

TempScan / MultiScan User's Manual 879596 System Configuration 4-9 Scan Configuration Configuring the Scan Channel Scan & Scan Inter

Página 272

4-10 System Configuration 879596 TempScan / MultiScan User's Manual Fast-Mode Scan Rate (Minimum Scan Interval) However, the scan interval

Página 273 - Reading HLL Status

TempScan / MultiScan User's Manual 879596 System Configuration 4-11 To Compute the TempScan/1100 Scan Interval To compute the time interval

Página 274

TempScan / MultiScan User's Manual vii Table of ContentsTempScan/MultiScan Quick Start Guide (p/n 446-0940) 1 - System Overview Introduction

Página 275

4-12 System Configuration 879596 TempScan / MultiScan User's Manual To Compute the MultiScan/1200 Scan Interval To compute the time interv

Página 276

TempScan / MultiScan User's Manual 879596 System Configuration 4-13 Acquisition Configuration Configuring the Acquisition (Non-Burst Mode)

Página 277

4-14 System Configuration 879596 TempScan / MultiScan User's Manual If the Pre-Trigger pre is set to a non-zero value, the TempScan/1100 o

Página 278 - (50) …… 15-WEND

TempScan / MultiScan User's Manual 879596 System Configuration 4-15 If the Post-Stop stop parameter of the Set Counts (Y) command is set to

Página 279

4-16 System Configuration 879596 TempScan / MultiScan User's Manual To enable the gap-free acquisition with two timebases, you must perfor

Página 280

TempScan / MultiScan User's Manual 879596 System Configuration 4-17 • Auto Re-arm: This parameter is the feature which determines whether

Página 281

4-18 System Configuration 879596 TempScan / MultiScan User's Manual The Trigger and Stop can each be assigned any of the following sources

Página 282

TempScan / MultiScan User's Manual 879596 System Configuration 4-19 Alarm Configuration The TempScan/1100 or MultiScan/1200 unit can be pro

Página 283

4-20 System Configuration 879596 TempScan / MultiScan User's Manual For example, let us assume a channel has alarm setpoints of 100 and -1

Página 284

TempScan / MultiScan User's Manual 879596 System Configuration 4-21 Comparing Buffered Data to Alarm Status Data With the TempScan/1100 uni

Página 285 - Operating Alarms

viii TempScan / MultiScan User's Manual 5 – System Operation Acquisition Buffer …… 5-1 Buffer Organization …… 5-2 Buffer Query Operation …… 5-

Página 286

4-22 System Configuration 879596 TempScan / MultiScan User's Manual Stamp Configuration Scan Time Stamping The contents of each scan conta

Página 287

TempScan / MultiScan User's Manual 879596 System Configuration 4-23 Example 12f. Scan Time Stamping Disabled (Default) (1) PRINT#1, “OUTP

Página 288

4-24 System Configuration 879596 TempScan / MultiScan User's Manual Example 12g. Scan Alarm Stamping Enabled (1) PRINT#1, “OUTPUT07;A#1X

Página 289

TempScan / MultiScan User's Manual 879596 System Configuration 4-25 With digital input stamping, the “on” (1) or “off” (0) states of the 8

Página 290

4-26 System Configuration 879596 TempScan / MultiScan User's Manual Data Format Configuration Readings from the TempScan/1100 or MultiScan

Página 291

TempScan / MultiScan User's Manual 879596 System Configuration 4-27 Data Output Formats During or after the acquisition, issuing the Set Da

Página 292

4-28 System Configuration 879596 TempScan / MultiScan User's Manual Engineering Units Format If the Engineering Units data format is selec

Página 293

TempScan / MultiScan User's Manual 879596 System Configuration 4-29 • Timebase (Scan Interval): The timebase (or scan interval) data will

Página 294

4-30 System Configuration 879596 TempScan / MultiScan User's Manual Binary-to-ASCII Number Conversion Tables One 4-Bit Binary Digit (Pos

Página 295

TempScan / MultiScan User's Manual 879596 System Configuration 4-31 Data Output Terminators In addition to formatting the data readings the

Página 296

TempScan / MultiScan User's Manual ix Appendix A - API Command Reference Introduction …… A-2 Command Syntax …… A-2 Command Interpretation ……

Página 297

4-32 System Configuration 879596 TempScan / MultiScan User's Manual Power-Up Configuration The TempScan/1100 or MultiScan/1200 unit has an

Página 298

TempScan / MultiScan User's Manual 889897 System Operation 5-1 System Operation 5 Acquisition Buffer …… 5-1 Buffer Organization …… 5-2 Buffer

Página 299

5-2 System Operation 889897 TempScan / MultiScan User's Manual Buffer Organization Single Trigger Block Each Trigger Block in the buffer has

Página 300

TempScan / MultiScan User's Manual 889897 System Operation 5-3 Buffer Buffer Read Pointer > Scan -76 Pre-Trigger Scans No longer

Página 301

5-4 System Operation 889897 TempScan / MultiScan User's Manual Trigger Overrun A Trigger overrun (as opposed to a buffer overrun) condition e

Página 302

TempScan / MultiScan User's Manual 889897 System Operation 5-5 • Time/Date Stamping of Stop Event (Field 6). Absolute ASCII format: hh:mm:

Página 303

5-6 System Operation 889897 TempScan / MultiScan User's Manual Note: The responses to all queries (including U6, R1, and R2) can be configure

Página 304

TempScan / MultiScan User's Manual 889897 System Operation 5-7 Part 2 – The Stop event has not yet occurred. The following describes a U6 res

Página 305

5-8 System Operation 889897 TempScan / MultiScan User's Manual Part 4 – The Trigger Block is now complete. The following describes a U6 resp

Página 306

TempScan / MultiScan User's Manual 889897 System Operation 5-9 Part 1 – The current Acquisition Buffer status. The Acquisition Buffer current

Modelos relacionados MultiScan/1200

Comentários a estes Manuais

Sem comentários