DAQFlex Software User's Guide DAQFlex Message Reference Programming messages AISCAN
45
HIGHCHAN
Set the last channel to include in the hardware-paced scan operation.
Message
"AISCAN:HIGHCHAN=value"
Response
"AISCAN:HIGHCHAN"
value
The channel number.
Example
"AISCAN:HIGHCHAN=3"
Get the last channel to include in the hardware-paced scan operation.
Message
"?AISCAN:HIGHCHAN"
Response
"AISCAN:HIGHCHAN=value"
value
The channel number.
INDEX
Get the current location of the pointer in the buffer.
Message
"AISCAN:INDEX=
Response
"AISCAN:INDEX"
value
The current location of the pointer in the buffer.
Example
"AISCAN:COUNT=765"
Note
INDEX tracks COUNT in finite mode, and recycles at BUFSIZE in continuous mode; this
accounts for sample size, number of channels, and so on.
LOWCHAN
Set the first channel to include in the hardware-paced scan operation.
Message
"AISCAN:LOWCHAN=value"
Response
"AISCAN:LOWCHAN"
value
The channel number.
Example
"AISCAN:LOWCHAN=0"
Get the first channel to include in the hardware-paced scan operation.
Message
"?AISCAN:LOWCHAN"
Response
"AISCAN:LOWCHAN=value"
value
The channel number.
QUEUE
Enable or disable the analog input gain queue.
Message
"AISCAN:QUEUE=value"
Response
"AISCAN:QUEUE"
value
ENABLE, DISABLE, or RESET