USB-4301 User's Guide Functional Details
14
29 INP3
30 GAT3
31 OUT3
32 INP4
33 GAT4
34 OUT4
35 INP5
36 GAT5
37 OUT5
38 GND
39
40
41
42
43
44
45
46
47
50 DO1
51 DO2
52 DO3
53 DO4
54 DO5
55 DO6
56 DO7
48 GND
49 DO0
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
INP1 1
GAT1 2
OUT1 3
INP2 4
GAT2 5
OUT2 6
OSC 7
+5V 8
INT 9
GND 10
RSVD 11
+5V 18
DI CTL 19
GND 20
DI0 21
DI1 22
DI2 23
DI3 24
DI4 25
DI5 26
DI6 27
DI7 28
12
13
14
15
16
17
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
Figure 4. USB-4301 signal pin out
Counter terminals (INP1 to INP5, GAT1 to GAT5, and OUT1 to OUT5)
The counter terminals provide the connections for the clock input signal and gate signal to each counter, and the
output signal from each counter. The clock, gate, and output sources are software-selectable. You can configure
each counter to count up or down.
Digital input (DI0 to DI7) and output (DO0 to DO7) terminals
You can connect up to eight digital input lines to the screw terminals labeled DI0 to DI7 (pins 21 through 28),
and up to eight digital output lines to the screw terminals labeled DO0 to DO7 (pins 49 through 56).
You can use the digital input terminals to detect the state of any TTL level input. Refer to the schematic shown
in Figure 5. When the switch is set to the +5V input, DI7 reads TRUE (1). If you move the switch to GND, DI7
reads FALSE (0).
+5V
GND
DI
7
Figure 5. Schematic showing switch detection by digital channel DI7
For more information on digital signal connections
For more information on digital signal connections and digital I/O techniques, refer to the Guide to Signal
Connections (available on our web site at www.mccdaq.com/signals/signals.pdf).