USB-1608FS User's Guide
11
Use 16 AWG to 30 AWG wire when making connections to the screw terminals. Pinout locations are shown in
Figure 3 below.
Figure 3. Screw terminal pinout
Signal connections
Analog input
You can connect up to eight analog input connections to CH0 IN through CH7 IN. Connect unused analog input
terminals to ground terminals during operation. For example, if you are not using terminal 15 (
CH7 IN), connect
this terminal to terminal 16 (
AGND).
The analog input channels are configured for single-ended input mode. Each analog signal is referenced to
signal ground (AGND), and requires two wires:
Connect the wire carrying the signal to be measured to
CH# IN.
Connect the second wire to
AGND.
The input voltage ranges are ±10 V, ±5 V, ±2.0 V, ±1.0 V.
For more information on analog signal connections
For more information on single-ended inputs, refer to the Guide to Signal Connections (this document is
available on our web site at www.mccdaq.com/signals/signals.pdf).