Measurement-computing Personal Daq rev.6.0 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Measurement-computing Personal Daq rev.6.0. Measurement Computing Personal Daq rev.6.0 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Personal Daq User’s Manual
USB Data Acquisition Modules
Personal Daq/54
Personal Daq/55
Personal Daq/56
PDQ1
PDQ2
IOtech, Inc.
25971 Cannon Road
Cleveland, OH 44146-1833
Phone: (440) 439-4091
Fax: (440) 439-4093
e-mail (Product Information):
e-mail (Technical Support): productsupport@iotech.com
Internet: http://www.iotech.com
Personal Daq
User’s Manual
p/n 491-0901, rev 6.0
© 1998 … 2005 by IOtech, Inc. 878695 Printed in the United States of America
Vista de página 0
1 2 3 4 5 6 ... 169 170

Resumo do Conteúdo

Página 1 - Personal Daq

Personal Daq User’s Manual USB Data Acquisition Modules Personal Daq/54 Personal Daq/55 Personal Daq/56 PDQ1 PDQ2 IOtech, In

Página 2

1-2 Unit Startup 878395 Personal Daq User’s Manual CAUTION When using Personal Daq modules to acquire data, computer energy save modes c

Página 3

5-4 Signal Management 878695 Personal Daq User’s Manual Signal Acquisition Measurement Duration, Sample Rate, and Resolution Measurement D

Página 4 - 1086-0922

Note: Frequency channels will read frequency regardless of the scan rate. Personal Daq circuitry reads a pulse count and timer count during each sca

Página 5 - About This Manual

• The pre-trigger scan count specifies the number of scans that are to be collected before the trigger point. If the pre-trigger scan count is great

Página 6

In the schematic, voltage signal S2 is subtracted from signal S1, resulting in the output signal shown. The noise spikes (having the same polarity, p

Página 7 - Table of Contents

Analog Filtering A filter is an analog circuit element that attenuates an incoming signal according to its frequency. A low-pass filter attenuates fr

Página 8 - 6 - Calibration

Calibration 6 Introduction ……6-1 Required Equipment ……6-2 Calibration Procedure ……6-2 Introduction Although Personal

Página 9 - Unit Startup 1

Required Equipment You will need the following items to perform Personal Daq calibration. Ensure the equipment meets the specifications listed in the

Página 10 - Install Hardware

It is important to perform calibration in a controlled, still air environment at 23±2°C. Personal Daq User’s Manual 878395 Calibration

Página 11 - Unit Startup 1-3

7. Make the following 3 voltage-related connections (see following figure). • Copper short: From Personal Daq Analog In 2L (2 low) to Personal Daq

Página 12 - Personal Daq User’s Manual

19. If your Personal Daq is connected to an expansion module: - remove the USB cable from the Personal Daq main unit - if used in your application

Página 13 - CAUTION

Personal Daq User’s Manual 878395 Unit Startup 1-3 Mount Personal Daq Modules to DIN Rail (Option) The optional PDQ10 DIN Rail Mounting Kit c

Página 14

6-6 Calibration 878395 Personal Daq User’s Manual 22. Disconnect the calibration equipment from the Personal Daq • VDC Calibrator • Harness an

Página 15 - Start Personal DaqView

Troubleshooting & Customer Assistance 7 Radio Frequency Interference …… 7-1 Electrostatic Discharge (ESD) …… 7-1 Troubleshooting …… 7

Página 16 - Configure System

7-2 Troubleshooting & Customer Assistance 878495 Personal Daq User’s Manual Troubleshooting Certain problems can be solved without fact

Página 17 - Acquisition Configuration

Personal Daq User’s Manual 878495 Troubleshooting & Customer Assistance 7-3 3. There is a “blue screen” or an error message when connect

Página 18 - Collect Data

7-4 Troubleshooting & Customer Assistance 878495 Personal Daq User’s Manual 7. Personal DaqView runs fine with analog inputs, but “bl

Página 19 - PDAQ.BIN, is as follows:

Customer Assistance Reference Notes: Before calling for assistance . . . • Refer to the portions of this manual relevant to your situation, especial

Página 20

7-6 Troubleshooting & Customer Assistance 878495 Personal Daq User’s Manual

Página 21 - ---- N/A ---- ---- N/A

Appendices Appendix A ⎯ API Custom Program Models Appendix B ⎯ API Commands Appendix C ⎯ Removed Appendix D ⎯ Custom Labels Note: The inf

Página 22 - Features

A-ii Personal DaqView User’s Manual

Página 23 - Theory of Operation

Personal Daq User’s Manual Appendix A, 887095 API Custom Program Modules A-1 API Custom Program Models A Ove

Página 24 - Input Ranges

1-4 Unit Startup 878395 Personal Daq User’s Manual 3) Attach Assembly to DIN Rail (Types NS 35, or NS 32) Installing Base/Foot Assembly

Página 25 - Analog Input Configuration

• Channel Identification • Scan Rates and Sequencing With multiple scans, the time between scans becomes a parameter. This time can be a constant o

Página 26

Personal Daq User’s Manual Appendix A, 878495 API Custom Program Modules A-3 All Visual Basic pr

Página 27 - Thermocouple Measurements

At this point, the data is in the buffer provided by the user in binary format.At this point, the data is in the buffer provided by the user in binary

Página 28

Counted Acquisitions Using Linear Buffers This section sets up an acquisition that collects post-trigger A/D scans. This particular example demonstra

Página 29

A-6 API Custom Program Modules Appendix A, 878495 Personal Daq User’s Manual The acquisition begins upon dete

Página 30 - Input Voltage Ranges

Indefinite Acquisition, Direct-To-Disk Using Circular Buffers Configure a scan group of channels.Set the samplingrate.Configure the acquisitionto be i

Página 31 - Thermocouple Accuracy

A-8 API Custom Program Modules Appendix A, 878495 Personal Daq User’s Manual ' Define arrays of channels

Página 32 - Optional Accessories

Personal Daq User’s Manual Appendix A, 878495 API Custom Program Modules A-9 After setting up an

Página 33 - Channel Connection Layouts

Multiple Channel Types This section demonstrates how to configure multiple channels on a Personal Daq and acquire data using these channels in the sa

Página 34

Personal Daq User’s Manual Appendix A, 878495 API Custom Program Modules A-11 The handle& va

Página 35 - Calibration

Personal Daq User’s Manual 878395 Unit Startup 1-5 CAUTION Never remove a USB cable from an active Personal Daq device while an acquisitio

Página 36

A-12 API Custom Program Modules Appendix A, 878495 Personal Daq User’s Manual If the handle is still –1 at th

Página 37 - Hardware Setup 3

Personal Daq User’s Manual Appendix A, 878495 API Custom Program Modules A-13 ret& = VBdaqSe

Página 38 - PDQ Expansion Modules

A-14 API Custom Program Modules Appendix A, 878495 Personal Daq User’s Manual Summary Guide of Selected API

Página 39 - USB Hubs and Power Adapters

Personal Daq User’s Manual Appendix B, 887095 API Commands B-1 API Commands B Overview This appendix includes information regarding

Página 40 - 3-4 Hardware Setup

B-2 API Commands Appendix B, 887095 Personal Daq User’s Manual Prototype Commands, Listed by Function Type (as defined in driver header files

Página 41 - Hardware Setup 3-5

Personal Daq User’s Manual Appendix B, 887095 API Commands B-3 Commands in Alphabetical Order The following pages give the details for each API

Página 42 - 3-6 Hardware Setup

B-4 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcDisarm DLL Function daqAdcDisarm(DaqHandleT handle); C daqAdcDisarm(Daq

Página 43

Personal Daq User’s Manual Appendix B, 887095 API Commands B-5 daqAdcRd DLL Function daqAdcRd(DaqHandleT handle, DWORD chan, PVOID sample, da

Página 44

B-6 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcRdN DLL Function daqAdcRdN(DaqHandleT handle, DWORD chan, PVOID buf, DWO

Página 45 - Main Control Window

Personal Daq User’s Manual Appendix B, 887095 API Commands B-7 daqAdcRdScan DLL Function daqAdcRdScan(DaqHandleT handle, DWORD startChan, DWOR

Página 46 - Pull-Down Menus

1-6 Unit Startup 878395 Personal Daq User’s Manual Connect Channel Signal Inputs CAUTION The discharge of static electricity can damage som

Página 47 - Measurement Units

B-8 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcRdScanN DLL Function daqAdcRdScanN(DaqHandleT handle, DWORD startChan, D

Página 48 - Channel Configuration Window

Personal Daq User’s Manual Appendix B, 887095 API Commands B-9 daqAdcSetAcq DLL Function daqAdcSetAcq(DaqHandleT handle, daqAdcAcqMode mode, D

Página 49 - Common Spreadsheet Columns

B-10 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcSetDataFormat DLL Function daqAdcSetDataFormat(DaqHandleT handle, daqAd

Página 50 - (b) for the application in

Personal Daq User’s Manual Appendix B, 887095 API Commands B-11 daqAdcSetFilter DLL Function daqAdcSetFilter(DaqHandleT handle, DaqAdcFilterTyp

Página 51 - cell for PD1_A01, typed

B-12 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcSetMux DLL Function daqAdcSetMux(DaqHandleT handle, DWORD startChan, DW

Página 52 - Analog Input Spreadsheet

Personal Daq User’s Manual Appendix B, 887095 API Commands B-13 daqAdcSetScan DLL Function daqAdcSetScan(DaqHandleT handle, PDWORD channels, d

Página 53 - Measurement Duration Column

B-14 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcSetTrigEnhanced DLL Function daqAdcSetTrigEnhanced(DaqHandleT handle, d

Página 54

Personal Daq User’s Manual Appendix B, 887095 API Commands B-15 daqAdcSoftTrig DLL Function daqAdcSoftTrig(DaqHandleT handle); C daqAdcSoftTri

Página 55 - Resolution and Settling Time

B-16 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcTransferGetStat DLL Function daqAdcTransferGetStat(DaqHandleT handle, P

Página 56 - 4-14 Personal DaqView

Personal Daq User’s Manual Appendix B, 887095 API Commands B-17 daqAdcTransferSetBuffer DLL Function daqAdcTransferSetBuffer(DaqHandleT handl

Página 57

Personal Daq User’s Manual 878395 Unit Startup 1-7 Connecting Thermocouple Wires Thermocouple wires are to be connected in differential mod

Página 58 - Averaging

B-18 API Commands Appendix B, 887095 Personal Daq User’s Manual daqAdcTransferStart DLL Function daqAdcTransferStart(DaqHandleT handle); C da

Página 59 - Acquisition Parameters

Personal Daq User’s Manual Appendix B, 887095 API Commands B-19 daqCloseList DLL Function daqCloseList(DaqHandleT handle); C daqCloseList(Daq

Página 60 - 4-18 Personal DaqView

B-20 API Commands Appendix B, 887095 Personal Daq User’s Manual daqCvtSetAdcRange DLL Function daqCvtSetAdcRange(FLOAT Admin, FLOAT Admax); C

Página 61 - Disabling Auto Rearm

Personal Daq User’s Manual Appendix B, 887095 API Commands B-21 daqGetDeviceCount DLL Function daqGetDeviceCount(DWORD *deviceCount); C daqGet

Página 62 - Meter Toolbars

B-22 API Commands Appendix B, 887095 Personal Daq User’s Manual daqGetDriverVersion DLL Function daqGetDriverVersion(PDWORD version); C daqGe

Página 63 - Meters Configuration Menu

Personal Daq User’s Manual Appendix B, 887095 API Commands B-23 daqIOReadBit DLL Function daqIOReadBit(DaqHandleT handle, daqIODeviceType dev

Página 64 - Configuring a Meter

B-24 API Commands Appendix B, 887095 Personal Daq User’s Manual daqIOWriteBit DLL Function daqIOWriteBit(DaqHandleT handle, daqIODeviceType d

Página 65

Personal Daq User’s Manual Appendix B, 887095 API Commands B-25 daqOpen DLL Function daqOpen(LPSTR daqName); C daqOpen(LPSTR daqName); Visual

Página 66 - Bar Graph Meters

B-26 API Commands Appendix B, 887095 Personal Daq User’s Manual daqProcessError DLL Function daqProcessError(DaqHandleT handle, daqError errC

Página 67 - Analog Meters

Personal Daq User’s Manual Appendix B, 887095 API Commands B-27 daqSetOption DLL Function daqSetOption(DaqHandleT handle, DWORD chan, DWORD fl

Página 68 - Digital Meters

1-8 Unit Startup 878395 Personal Daq User’s Manual Configure System This step pertains to configuration of channels and acquisition paramete

Página 69 - Chart Display

B-28 API Commands Appendix B, 887095 Personal Daq User’s Manual daqWaitForEvent DLL Function daqWaitForEvent(DaqHandleT handle, daqTransferEv

Página 70

Personal Daq User’s Manual Appendix B, 887095 API Commands B-29 API Reference Tables These tables provide information for programming with the

Página 71 - Toolbar Items

B-30 API Commands Appendix B, 887095 Personal Daq User’s Manual Table 1. daq Device Property Definitions daqG

Página 72 - Item Description

Personal Daq User’s Manual Appendix B, 887095 API Commands B-31 Table 3. Event-Handling Definitions Transfer Event Definitions - daqTrans

Página 73

B-32 API Commands Appendix B, 887095 Personal Daq User’s Manual Table 7. ADC Miscellaneous Definitions ADC Flag Definitions - daqAdcFlag A

Página 74

Personal Daq User’s Manual Appendix B, 887095 API Commands B-33 Table 9. API Error Codes Error Name Code # hex - dec Description DerrNoE

Página 75

B-34 API Commands Appendix B, 887095 Personal Daq User’s Manual API Error Codes DerrTooManyHandles 60h - 96 No more handles available to ope

Página 76 - 4-34 Personal DaqView

Personal Daq User’s Manual, 878695 Appendix D Custom Labels D-1 Custom Labels D This appendix consists of

Página 77

D-2 Custom Labels Appendix D Personal Daq User’s Man

Página 78 - 4-36 Personal DaqView

Channel Connection Layouts, Page 1 of 2 Personal Daq User’s Manual, 878695 Appendix D Custom Labels D-3

Página 79 - Chart Setup Wizard

Personal Daq User’s Manual 878395 Unit Startup 1-9 Channel Configuration The Channel Configuration Window first opens with the Analog Input

Página 80

Channel Connection Layouts, Page 2 of 2 D-4 Custom Labels Appendix D

Página 81

1-10 Unit Startup 878395 Personal Daq User’s Manual The Configure Acquisition Window has the following default settings. Pre-Trigger: No du

Página 82 - 4-40 Personal DaqView

Personal Daq User’s Manual 878395 Unit Startup 1-11 Quick Start for Personal DaqView Once your Personal Daq system has been properly connecte

Página 84 - First Time Use

1-12 Unit Startup 878395 Personal Daq User’s Manual Main Control Window Channel Configuration Window, with Analog Input Spreadsheet Selec

Página 85

Personal Daq User’s Manual 878695 General Information & Specifications 2-1 General Information & Specifications 2 General De

Página 86

2-2 General Information & Specifications 878595 Personal Daq User’s Manual Note: With the use of USB hubs up to 100 Personal Daq units ca

Página 87 - Configuration Reference

Personal Daq User’s Manual 878595 General Information & Specifications 2-3 Theory of Operation Universal Serial Bus (USB) The Universal Seri

Página 88

2-4 General Information & Specifications 878595 Personal Daq User’s Manual Optical Isolation The Personal Daq is optically isolated from i

Página 89

Personal Daq User’s Manual 878595 General Information & Specifications 2-5 Analog Input Configuration Personal Daq/54 and Personal Daq/55 eac

Página 90 - Auto-Load Function

2-6 General Information & Specifications 878595 Personal Daq User’s Manual At a measurement duration of 610 milliseconds, the last two bit

Página 91

Personal Daq User’s Manual 878595 General Information & Specifications 2-7 Automatic Calibration The Personal Daq module contains a built-in

Página 92

2-8 General Information & Specifications 878595 Personal Daq User’s Manual Frequency Measurements (Not applicable to Personal Daq/54) Eac

Página 93 - Real-Time Charting

Personal Daq User’s Manual 878595 General Information & Specifications 2-9 Personal Daq Specifications Specifications are subject to c

Página 94 - Data Header

Warranty Information Your IOtech warranty is as stated on the product warranty card. You may contact IOtech by phone, fax machine, or e-mail in reg

Página 95 - Hints and Tips

2-10 General Information & Specifications 878595 Personal Daq User’s Manual Analog Specifications Each channel can be individually configu

Página 96

Personal Daq User’s Manual 878595 General Information & Specifications 2-11 Temperature Specifications (one year, 15 to 35°C) Note: All te

Página 97

2-12 General Information & Specifications 878595 Personal Daq User’s Manual Frequency Specifications, one year 0 to 50°C (Not applicab

Página 98

Personal Daq User’s Manual 878595 General Information & Specifications 2-13 Channel Connection Layouts The following indicate channel connect

Página 99

2-14 General Information & Specifications 878595 Personal Daq User’s Manual In Personal Daq applications, thermocouples should not be co

Página 100 - Signal Acquisition

Personal Daq User’s Manual 878595 General Information & Specifications 2-15 Note: The digital output can be written to since the digital out

Página 101 - Triggering

2-16 General Information & Specifications 878595 Personal Daq User’s Manual This page is intentionally blank.

Página 102 - Signal Modes

Personal Daq User’s Manual 878695 Hardware Setup 3-1 Hardware Setup 3 Personal Daq, System Components ……3-2 Personal Daq …… 3-2 PDQ Expansi

Página 103 - System Noise

3-2 Hardware Setup 878695 Personal Daq User’s Manual Personal Daq, System Components Personal Daq The following illustration points out key physi

Página 104 - Analog Filtering

Personal Daq User’s Manual 878695 Hardware Setup 3-3 USB Hubs and Power Adapters With the use of USB hubs you can connect up to 100 Personal Daq

Página 105 - Introduction

Your order was carefully inspected prior to shipment. When you receive your system, carefully unpack all items from the shipping carton and check f

Página 106 - Calibration Procedure

3-4 Hardware Setup 878695 Personal Daq User’s Manual Connecting Your Personal Daq Acquisition System Review the CAUTIONS and notes (presented

Página 107 - 878395 Calibration 6-3

Personal Daq User’s Manual 878695 Hardware Setup 3-5 Example 1: Direct Connection to Computer USB Port(s) In example 1 two Personal Daqs (and

Página 108

3-6 Hardware Setup 878695 Personal Daq User’s Manual Example 3: Connections to Self-Powered and USB-Powered Hubs Example 3 illustrates a system

Página 109 - 878395 Calibration 6-5

Personal DaqView 4 Overview …… 4-2 Standard, Plus, and XL Version Software …… 4-2 Main Control Window …… 4-3 Toolbar Buttons

Página 110

4-2 Personal DaqView 989394 Personal Daq User’s Manual Overview This chapter serves as a reference for Personal DaqView, Personal DaqView Plus,

Página 111 - Radio Frequency Interference

Main Control Window When you first open Personal DaqView the Main Control and Channel Configuration Windows appear. Note that this section pertains to

Página 112 - Troubleshooting

4-4 Personal DaqView 989394 Personal Daq User’s Manual Pull-Down Menus Aside from using the toolbar buttons to perform various program functions

Página 113

Personal Daq User’s Manual 989394 Personal DaqView 4-5 You can set preferences for Personal DaqView through the Preferences dialog box found unde

Página 114

4-6 Personal DaqView 989394 Personal Daq User’s Manual Help Contents and Index Accesses the program’s Help file. Contents include: Introduc

Página 115 - Customer Assistance

Personal Daq User’s Manual 989394 Personal DaqView 4-7 Common Spreadsheet Columns The Channel Configuration Window, regardless of which tab is ac

Página 116

About This Manual Chapter 1: Personal Daq ⎯ Unit Startup provides information to get your Personal Daq system up and running. The chapter includes i

Página 117 - Appendices

4-8 Personal DaqView 989394 Personal Daq User’s Manual Engineering Units Conversion Using mx + b Most of our data acquisition products allow the

Página 118

Example 2: A Personal Daq user knows that a linear relationship exists between the voltage output at "Point A" and the voltage output at &qu

Página 119 - Data Acquisition Environment

4-10 Personal DaqView 989394 Personal Daq User’s Manual Analog Input Spreadsheet The Analog Input spreadsheet allows you to configure analog inp

Página 120 - Programming Models

Single-Ended and Differential Connections to Analog Inputs In Personal Daq applications, thermocouples should not be connected single-ended. Doing

Página 121

4-12 Personal DaqView 989394 Personal Daq User’s Manual When you select the measurement duration you also determine the maximum sample rate and

Página 122 - Read 1 sample from multiple

Debounce ⎯ Debouncing is a process of ignoring signals which are considered as too short in duration to be real events. Personal Daq's debounce

Página 123

4-14 Personal DaqView 989394 Personal Daq User’s Manual The frequency is calculated as follows: 1) An estimated frequency (Fest) is calculated

Página 124

When an active (On) channel is selected to “Output State” the Update Digital Outputs button (on the Main Control Window) becomes active. This button

Página 125 - Buffers

4-16 Personal DaqView 989394 Personal Daq User’s Manual The Trigger Section The following figure depicts the parts that make up an acquisition.

Página 126

Personal Daq User’s Manual 989394 Personal DaqView 4-17 Acquisition Parameters The lower section of the Configure Acquisition box is used for adj

Página 127

vi 887695 Personal Daq User’s Manual

Página 128 - Multiple Channel Types

4-18 Personal DaqView 989394 Personal Daq User’s Manual Configure Data Destination and File Converter Preferences Conversion of eZ-PostView, eZ

Página 129

You can select Convert Binary Data from the Tools pull-down menu to bring up the following dialog box. This allows you to select a file for conversio

Página 130

4-20 Personal DaqView 989394 Personal Daq User’s Manual Bar Graph, Analog, and Digital Meters This section pertains to channel data display scre

Página 131

Meter Pull-Down Menus The meter windows each have Control and View pull-down menus, as indicated by the following figure. The functions of these menu

Página 132

4-22 Personal DaqView 989394 Personal Daq User’s Manual Configuring a Meter 1. Bring up the desired meter group (Bar Graph, Analog, or Digital)

Página 133 - API Commands B

Personal Daq User’s Manual 989394 Personal DaqView 4-23 Configure Meter Settings, Function Descriptions Note 1: Bar Graph Meter with indicato

Página 134

4-24 Personal DaqView 989394 Personal Daq User’s Manual Bar Graph Meters Selecting the Bar Graph Meters (from toolbar button or Indicators pull-

Página 135

Analog Meters Selecting the Analog Meters (from toolbar button or Indicators pull-down menu) brings up the Analog Meters window. This window display

Página 136

4-26 Personal DaqView 989394 Personal Daq User’s Manual Digital Meters Selecting the Digital Meters (from toolbar button or Indicators pull-down

Página 137

Chart Display Reference Note: For your very first chart display setup, or when the configuration file has been deleted, refer to the Chart Setup Wi

Página 138

Table of Contents 1 - Personal Daq ⎯ Unit Startup Overview ……1-1 Inspect Your System ……1-1 Install Software ……1-2 Install Hardware ……1-2 Mount

Página 139

4-28 Personal DaqView 989394 Personal Daq User’s Manual Personal DaqView’s Chart Display Window Note: A discussion of the numbered buttons and

Página 140

View Grid Limit Lines Used to show or hide the grid limit lines. Grid Lines Used to show or hide the grid lines. Timestamp Absolute (Ctrl+F4)

Página 141

4-30 Personal DaqView 989394 Personal Daq User’s Manual Chart and Channel Information Regions Channels can return values in engineering units of

Página 142

15 Multiply (x2), and 16 Divide (÷2) The Multiply(x2) push-button increases the size of the selected channel’s chart by a factor of 2, while automat

Página 143

4-32 Personal DaqView 989394 Personal Daq User’s Manual Editing a Chart Display Configuration Display Configuration Setup Dialog Box wi

Página 144

Changing the Configuration of Channel PD1_A01 Personal DaqView data channels can operate in one of two modes: Units Full Scale or, Units/Div. The mo

Página 145

4-34 Personal DaqView 989394 Personal Daq User’s Manual Manually Configuring a Chart Display If you plan to have a chart setup which is not weig

Página 146

Adding one Chart to Group 1 4. Change the number of charts per group if desired. 5. Change the group na

Página 147

4-36 Personal DaqView 989394 Personal Daq User’s Manual Note: When a chart contains overlapping channels and the channels share values such tha

Página 148

Chart Setup Wizard Introduction Chart Setup Wizard is a feature used by many programs, including Personal DaqView, and PostView. The feature allows

Página 149

5 – Signal Management Overview ……5-1 Channel Control and Expansion ……5-3 Signal Acquisition ……5-3 Measurement Duration, Sample Rate, and Resolution …

Página 150

4-38 Personal DaqView 989394 Personal Daq User’s Manual Chart Setup Wizard, Simple Mode Chart Setup Wizard, Automatic Setup Options Setup Type

Página 151

Personal Daq User’s Manual 989394 Personal DaqView 4-39 3. Use the pull-down arrows (W), or use the cursor and type in a new value to make selec

Página 152

4-40 Personal DaqView 989394 Personal Daq User’s Manual

Página 153

Personal DaqViewXL User’s Guide TM OverView …… 1 System Requirements …… 2 Installation …… 2 First Time Use …… 2 Configuration Reference …… 5 Toolbar

Página 154

System Requirements For successful operation of Personal DaqViewXL with your Personal Daq system, your computer should conform to the following as a

Página 155

3. Click the “Browse” button and locate the file pDaqView.xla. This file is located in the install directory specified by the setup program. Click

Página 156

After Personal DaqViewXL is installed in this manner, it will automatically load whenever you run Excel. 6. If you want to start Personal DaqView wh

Página 157

Configuration Reference The following information is intended to serve as a quick reference regarding channel configuration. You should refer to the

Página 158

10 Update Digital Outputs Updates the digital output channels. This item is only enabled when the digital output channels are not updated and the a

Página 159

Channel Configuration Window You can bring up the Channel Configuration Window by using the Configure Channel Settings button (9) on the Main Contro

Página 160

Personal Daq User’s Manual 878395 1-1 Unit Startup 1 Overview ……1-1 Inspect Your System ……1-1 Install Software ……1-2 Install Hardware ……1-2 Mount

Página 161 - Personal Daq/54)

8 491-0905, rev 3.0 918596 Personal DaqViewXL User’s Guide Auto-Load Function Excel’s “Add-Ins” dialog box has a check-box for enabling (9) or d

Página 162

Personal DaqViewXL Spreadsheet with Toolbar and Displays Personal DaqViewXL Toolbar (1) Configure Devices (2) Configure Channels (3) Configure Ac

Página 163 - Note: Includes “NE” version

Configuring an Acquisition To set up your configuration, once Personal DaqViewXL has been installed; complete the following steps: 1. Enter Excel. P

Página 164

Real-Time Charting Personal DaqViewXL provides a real-time strip-chart window (as in Personal DaqView) for graphical presentation of data. You can se

Página 165 - Table 9. API Error Codes

Data Header Personal DaqViewXL’s optional data header supplies the global acquisition parameters and the configuration of each channel and places this

Página 166 - 83h - 131

Personal DaqViewXL User’s Guide 918596 491-0905, rev 3.0 13 Hints and Tips • If Personal DaqView is running as a stand-alone application when y

Página 167

14 491-0905, rev 3.0 918596 Personal DaqViewXL User’s Guide

Página 168

Personal Daq User’s Manual 928196 Signal Management 5-1 Signal Management 5 Overview ……5-1 Channel Control and Expansi

Página 169

5-2 Signal Management 878695 Personal Daq User’s Manual Data Acquisition Terms and Meanings Differential mode voltage Differential mode v

Página 170

Personal Daq User’s Manual 878695 Signal Management 5-3 Channel Control and Expansion In a Personal Daq system, the quantities and types of Per

Comentários a estes Manuais

Sem comentários