Measurement-computing Personal Daq/3000 Series Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Hardware Measurement-computing Personal Daq/3000 Series. Measurement Computing Personal Daq/3000 Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 86
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
USER’S MANUAL
Personal Daq/3000 Series
USB 1-MHz, 16-Bit Multifunction Modules
Personal Daq/3000
Personal Daq/3001
Personal Daq/3005
Personal Daq/3000 Series
1136-0901 rev 2.1
*372751A-01*
372751-01
Measurement Computing
10 Commerce Way
Norton, MA 02766
(508) 946-5100
Fax: (508) 946-9500
www.mccdaq.com
Vista de página 0
1 2 3 4 5 6 ... 85 86

Resumo do Conteúdo

Página 1 - Personal Daq/3000 Series

USER’S MANUAL Personal Daq/3000 Series USB 1-MHz, 16-Bit Multifunction Modules Personal Daq/3000Personal Daq/3001Personal Daq/3005

Página 2

1-2 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Block Diagram for Personal Daq/3005 Connections Reference N

Página 3

Product Features I/O Comparison Matrix Product or System Analog InputChannels Input Ranges Analog OutputChannels Digital I/O Channels Counter Inputs

Página 4

1-4 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Signal I/O Six banks of removable screw-terminal blocks pro

Página 5 - Table of Contents

Example 1: Analog channel scanning of voltage inputs The figure below shows a simple acquisition. The scan is programmed pre-acquisition and is mad

Página 6

1-6 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Example 2: Analog channel scanning of voltage and temperatur

Página 7 - Step 1 – Install Software

Example 3: Analog and digital channel scanning, once per scan mode The figure below shows a more complicated acquisition. The scan is programmed pre

Página 8 - *324400D-01*

1-8 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Example 4: Sampling digital inputs for every analog sample i

Página 9 - Device Overviews 1

USB2.0 versus USB1.1 Connecting a Personal Daq/3000 Series device to a USB1.1 port or hub will result in lower transfer speed which may not support c

Página 10 - Connections

1-10 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Digital Triggering. A separate digital trigger input line

Página 11 - Product Features

Calibration Every range of a Personal Daq/3000 Series device is calibrated at the factory using a digital NIST traceable calibration method. This meth

Página 13

1-12 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Digital Inputs and Outputs Twenty-four TTL-level digital I/

Página 14

Example 5: Analog channel scanning of voltage inputs and streaming analog outputs The figure below shows a simple acquisition. The scan is programme

Página 15

1-14 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Counter Inputs Each Personal Daq/3000 Series module include

Página 16

Personal Daq/3000 Series User’s Manual 988093 Daq Systems and Device Overviews 1-15 Multiple Personal Daqs Multiple modules can be operated syn

Página 17 - Triggering

1-16 Daq Systems and Device Overviews 988093 Personal Daq/3000 Series User’s Manual Reference Notes: o The software documents for: DaqView, V

Página 18

Connections and Pinouts 2 Overview …… 2-1 Pinout for Personal Daq/3000 Series Modules …… 2-2 PDQ30 Analog Expansion Option …… 2-3 Connecting for Sing

Página 19 - Analog Output

2-2 Connections & Pinouts 888594 Personal Daq/3000 Series User’s Manual Pinout for Personal Daq/3000 Series Modules USB2.0 Edge of Module

Página 20 - Digital Inputs and Outputs

PDQ30 Analog Expansion Option PDQ30 is an optional analog expansion module that, when connected to a Personal Daq/3000 series device, adds an additio

Página 21

Pinout for PDQ30 DSUB25 Edge of PDQ30 Module Analog Common Analog CH 63 / CH 31 LO CH 16 / CH 8 HI Analog Analog CH 55 / CH 3

Página 22 - Timer Outputs

Connecting for Single-Ended or Differential Voltage signals can be connected using the Single-Ended method. In the following figure voltage source

Página 23 - Software

Warranty Information Contact Measurement Computing by phone, fax, or e-mail in regard to warranty-related issues: Phone: (508) 946-5100, fax: (508) 9

Página 24

2-6 Connections & Pinouts 888594 Personal Daq/3000 Series User’s Manual

Página 25 - Connections and Pinouts 2

CE-Compliance 3 Overview ……3-1 CE Standards and Directives …… 3-1 Safety Conditions ……3-2 Emissions/Immunity Conditions ……3-2 Overview CE standard

Página 26

For clarification, terms used in some Declarations of Conformity include: • pollution degree: any addition of foreign matter, solid, liquid or gaseo

Página 27 - CAUTION

Calibration 4 The DaqCal.exe calibration utility does not support Personal Daq/3000 Series devices at present. Please contact the factory for the l

Página 28 - Pinout for PDQ30

4-2 Calibration 898194 Personal Daq/3000 Series User’s Manual

Página 29

Counter Input Modes 5 Tips for Making High-Speed Counter Measurements ( > 1 MHz ) …… 5-1 Debounce Module …… 5-1 Terms Applicable to Counter Modes

Página 30

Trigger After Stable Mode In the “Trigger After Stable” mode, the output of the debounce module will not change state until a period of stability has

Página 31 - CE-Compliance 3

T2 – During time period T2, the input signal is not stable for a length of time equal to T1 (the debounce time setting for this example.) Therefore,

Página 32 - Safety Conditions

Use trigger before stable mode when the input signal has groups of glitches and each group is to be counted as one. The trigger before stable mode w

Página 33 - 898194 Calibration 4-1

Personal Daq/3000 Series User’s Manual 887894 Counter Input Modes 5-5 Terms Applicable to Counter Modes The following terms and definitions ar

Página 34

iv Your order was carefully inspected prior to shipment. When you receive your system, carefully unpack all items from the shipping carton

Página 35 - Counter Input Modes 5

Encoder Mode (see page 15). OPT[1:0]: Determines the encoder measurement mode: 1X, 2X, or 4X. OPT2: Determines whether the counter is 16-bits (Coun

Página 36

An explanation of the various counter options, depicted in the previous figure, follows. COUNTER: OPT0: This selects totalize or clear on read mode

Página 37

Period Mode TIP: When using a counter for a trigger source, it is a good idea to use a pre-trigger with a value of at least 1. The reason is that

Página 38

Personal Daq/3000 Series User’s Manual 887894 Counter Input Modes 5-9 PERIOD: OPT[1:0]: Determines the number of periods to time, per measur

Página 39

5-10 Counter Input Modes 887894 Personal Daq/3000 Series User’s Manual Upper 16-bits of the 32-bit counter Lower 16-bits of the 32-bit coun

Página 40 - Counter/Totalize Mode

Pulsewidth Mode TIP: When using a counter for a trigger source, it is a good idea to use a pre-trigger with a value of at least 1. The reason is t

Página 41

5-12 Counter Input Modes 887894 Personal Daq/3000 Series User’s Manual PULSEWIDTH: OPT2: Determines whether the pulsewidth is to be measured

Página 42 - Period Mode

Timing Mode TIP: When using a counter for a trigger source, it is a good idea to use a pre-trigger with a value of at least 1. The reason is that

Página 43

An Example of Timing Mode The following example represents one channel in timing mode. The time desired is between the rising edge on the input cha

Página 44

Encoder Mode TIP: When using a counter for a trigger source, it is a good idea to use a pre-trigger with a value of at least 1. The reason is tha

Página 45 - Pulsewidth Mode

Personal Daq/3000 Series User’s Manual 888494 v Table of Contents Personal Daq/3000 Series, Installation Guide (p/n 1136-0940) 1 – Device Overv

Página 46

Representation of Quadrature Encoder Outputs: A, B, and Z As the encoder rotates, the A (or B) signal is indicative of the distance the encoder has

Página 47 - Timing Mode

ENCODER: OPT[1:0]: This determines the encoder measurement mode: 1X, 2X, or 4X. ENCODER: OPT3: This determines which signal latches the counter o

Página 48

Wiring for 1 Encoder The following figure illustrates connections for one encoder to a Personal Daq/3000 module. The “A” signal must be connected to

Página 49 - Encoder Mode

A typical acquisition might take 6 readings off of the Personal Daq/3000 as illustrated below. The user determines the scan rate and the number of

Página 50

Wiring for 2 Encoders The following figure illustrates single-ended connections for two encoders. Differential connections are not applicable. Ground

Página 51

Setpoint Configuration for Output Control 6 Overview …… 6-1 Detecting Input Values …… 6-3Controlling Analog, Digital, and Timer Outputs …… 6-4P2C,

Página 52 - Wiring for 1 Encoder

Criteria Input Signal is Equal to X Action Driven by Condition Compare X To: Setpoint Definition: Update Conditions: Limit A or Limit B • Equal to

Página 53

Detecting Input Values All setpoints are programmed as part of the pre-acquisition setup, similar to setting up the analog path, debounce mode, or co

Página 54

Controlling Analog, Digital, and Timer Outputs Each setpoint can be programmed with an 8-bit digital output byte and corresponding 8-bit mask byte. Wh

Página 55 - …… 6-10

The setting of a detection window must be done with a scan period in mind. This applies to analog inputs and counter inputs. Quickly changing analog

Página 56 - (Choose 1)

vi 888494 Personal Daq/3000 Series User’s Manual 6 – Setpoint Configuration for Output Control Overview …… 6-1 Detecting Input Values …… 6-3 Contr

Página 57 - Detecting Input Values

P2C, DAC, or Timer Update Latency Setpoints allow DACs, timers, or P2C digital outputs to be updated very quickly. Exactly how fast an output can be

Página 58

More Examples of Control Outputs Detection on an Analog Input, DAC and P2C Updates Update Mode: Update on True and False Criteria: Ch 5 example: Bel

Página 59

In the example [upper portion of the preceding figure], the setpoint placed on analog Channel 5 updated DAC1 with 0.0V. The update occurred when Chan

Página 60

Using the Hysterisis Function Update Mode: N/A, the Hysterisis option has a forced update built into the function Criteria Used: window criteria for

Página 61

Using Multiple Inputs to Control One DAC Output Update Mode: Rising Edge, for each of 2 channels Criteria Used: Inside Window, for each of 2 channel

Página 62

The Setpoint Status Register Regardless of which software application you are using with a Personal Daq/3000 Series device, a setpoint status registe

Página 63

6-12 Setpoint Configuration for Output Control 887894 Personal Daq/3000 Series User’s Manual

Página 64

Specifications – Personal Daq/3000 Series and PDQ30 7 Personal Daq/3000 Series Specifications I/O Comparison Matrix Product or System Analog InputCh

Página 65 - The Setpoint Status Register

7-2 Specifications 937492 Note: Specifications are subject to change without notice. Analog Inputs Channels: 16 single-ended or 8 differential.

Página 66

Worst Case Temperature Measuerment Error vs. Personal Daq3000 Ambient Temperaturewith Thermocouple at 0ºC (Excludes Thermocouple Error);AutoZero Disab

Página 67 - General Specifications

1136-0940, rev 3.0 324400D-01 Printed in

Página 68 - Analog Inputs

7-4 Specifications 937492 Note: Specifications are subject to change without notice. Voltage Range* Accuracy ±(% Reading + % Range) 23ºC ±

Página 69 - Specifications 7-3

Per-Channel Error, External Power1-1.5-1.0-0.50.00.51.01.501234567ChannelError °C Per-Channel Error, USB Power1-2.5-2.0-1.5-1.0-0.50.00.51.01.501234

Página 70 - P-P Noise in Measurement (ºC)

7-6 Specifications 937492 Note: Specifications are subject to change without notice. A/D Specifications Type: Successive approximation Resoluti

Página 71 - Per-Channel Error, USB Power

Note: Specifications are subject to change without notice. 937492 Specifications 7-7 Triggering Trigger Source

Página 72 - Input Sequencer

7-8 Specifications 937492 Note: Specifications are subject to change without notice. Analog Outputs Applicable to Personal Daq/3000 and /300

Página 73

Pattern Generation Output Two of the 8-bit ports can be configured for 16-bit pattern generation. The pattern can be updated synchronously with an a

Página 74 - Digital I/O

7-10 Specifications 937492 Note: Specifications are subject to change without notice. Frequency/Pulse Generators One Timer Channel, Typical Ch

Página 75 - Counters

Note: Specifications are subject to change without notice. 937492 Specifications 7-11 PDQ30 Specifications G

Página 76 - Frequency/Pulse Generators

7-12 Specifications 937492 Note: Specifications are subject to change without notice. PDQ30 Type T Thermocouple Typical Performance of 12 PDQ

Página 77 - PDQ30 Specifications

Appendix A Signal Modes and System Noise Signal Modes …… A-1 Connecting Thermocouples to Screw-Terminal

Página 78 - Accessories and Cables

324400D-01 If using a TR-2, be sure to supply power from it to the Personal Daq/3000 before connecting the USB cable

Página 79 - Signal Modes

A-2 Signal Modes and System Noise 937492 Appendix A Connecting Thermocouples to Screw Terminal Blocks Personal Daq/3000 Series modules

Página 80 - 937492 Appendix A

Shielding Using shielded TC wire with the shield connected to analog common will result in further noise reduction. Personal Daq/3000 Series modules

Página 81 - TC Common Mode

A-4 Signal Modes and System Noise 937492 Appendix A Cold Junction Compensation Techniques The Personal Daq/3000 can measure up to 8 ch

Página 82 - Appendix A

System Noise Laboratory and industrial environments often have multiple sources of electrical noise. An AC power line is a source of 50/60 Hz noise.

Página 83 - System Noise

A-6 Signal Modes and System Noise 937492 Appendix A A solution to high source impedance in relation to multiplexers involves the use o

Página 84

Glossary 887194 G-1 Glossary Acquisition A collection of scans acquired at a specified rate as controlled by the sequencer. Analog A signal of va

Página 85 - Glossary 887194 G-1

G-2 887194 Glossary Differential mode voltage Differential mode voltage refers to a voltage difference between two signals

Página 86 - 887194 Glossary

Device Overviews 1 Block Diagrams …… 1-1 Connections …… 1-2 Product Features …… 1-3 Software ……1-15 DaqView can only be used with one Personal Daq

Comentários a estes Manuais

Sem comentários