NAP7000D User Manual (Version 1.0) ---- 34
Output via DDE Link button in the Digital output portion. This CB-7044 would
perform the digital output function.
Step 4: Entry the module address for the selected module.
Step 5: Select the exact baud rate in the Baud Rate Combo for the selected module.
Step 6: Select the status of checksum(Disable or Enable). Notice, the status of
checksum must be exact to your physical CB-7000 series module device. If you
select Enable, you must to enable checksum status for CB-7000 module. The default
setting for CB-7000 series module is disable.
The Step 4, Step 5 and Step 6 can be skipped if invoking setting Configuration for
7044 window with method 2.(please referring Fig 2-10)
Step 7: Clicking OK button to accept the setting.