Measurement-computing CB-COM-7013 Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
32
CB-7013, CB-7033 Users Manual
2.15 ~AAEV
Description: Enable/Disable Calibration
Syntax: ~AAEV[CHK](cr)
~ Delimiter character
AA Address of setting module (00 to FF)
E Command for enable/disable calibration
V 1=Enable/0=Disable calibration
Response: Valid Command: !AA[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no
response.
! Delimiter for valid command.
? Delimiter for invalid command.
AA Address of response module (00 to FF).
Example:
Command: $010 Receive: ?01
Perform addreess 01 span calibration, return not enable
calibration.
Command: ~01E1 Receive: !01
Set address 01 to enable calibration, returns successful.
Command: $010 Receive: !01
Preform address 01 span calibration, returns successful.